PHENIX filters

See the choice of models
+ -
Manufacturer Partenair
Categories Compressed air treatment, Compressed air filters
Water (Vapor)
Classe iso : 7
9876543210
Particles
Classe iso : 2
9876543210
Residual oil content (20°)
Classe iso : 3
9876543210

Dry particle filters - Grade D (1μm)

The PHENIX-D series dust filters are placed after adsorption dryers in order to stop dust from desiccant columns.

These micron filters make the air flow in the opposite direction: from the outside to the inside.

This collects the dust at the bottom of the bowl and removes it via the manual air vent.

To be installed after the adsorption dryer.

  • Particle filtration up to 1μ (ISO Class 8573 = 2)
  • Filter bowl with screw stop. Avoids overtightening, installation and removal without tools.
  • New: Thanks to the QR Code on the filter, you can easily find the manual and certificates for your PHENIX filter!
  • Manual drain as standard.
  • Maximum efficiency, minimum pressure drop: up to 55% less pressure drop!
  • Longer service life thanks to a specific pleating that increases the filtration area by 250% compared to a conventional element!
  • Colour coding of the filter elements: red.
  • Total internal and external corrosion protection by KTL Dip-Coating cataphoresis.
  • Filters in compliance with Directive 14/68 for pressure equipment for group 2 gases.
  • Design in accordance with ISO 12500.
  • Manufacturing certified to ISO 9001.
  • Silicone-free materials.
Model
     
Model Input connection Flowrate (m³/h) My wish
PNX 50 D 3/8“ 50
PNX 90 D 1/2“ 90
PNX 120 D 3/4“ 120
PNX 220 D 1 “ 220
PNX 370 D 1 “ 370
PNX 540 D 1 ¼“ 540
PNX 700 D 1 ½“ 700
PNX 820 D 2“ 820
PNX 1320 D 2“ 1320
PNX 1500 D 2 ½“ 1500
Advise me    

* Select the generic if you don't know which model to choose. The sales department will contact you to determine the appropriate model.

(*) Flow rates indicated according to ISO 7183 (20ºC and 1 bar absolute) under 7 bar relative

Pre-filtration 1µ

Their bodies, made of die-cast aluminium, are protected against corrosion by internal and external cataphoresis treatment.

The filter elements are equipped with an external pre-filtration layer made of polyester fibres, ultrasonically welded, offering much greater resistance and efficiency than traditional reticulated foam layers.

Detailed specifications

Pression Bars 4 5 6 7 8 9 10 11 12 13 14 15 16
Facteur x 0.63 0.75 0.88 1 1.12 1.25 1.37 1.49 1.62 1.74 1.86 1.98 2.10

Correction factor depending on operating pressure

Detailed specifications PNX-D
Quality class according to ISO 8573-1:2001 Particles: 2
Particle filtration
Compressed air temperature min/max 1°C / 120°C
Maximum operating pressure Depending on model
Pressure loss (initial) 55 mbars
Maximum recommended pressure loss 400 mbar
Element replacement frequency* 8,760 h / 12 months
(*) For normal dusting and correct air quality.