Manufacturer | Partenair |
Categories | Compressed air treatment, Compressed air filters |
Particles
|
Classe iso : 1
9876543210
|
Residual oil content (20°)
|
Classe iso : 1
9876543210
|
Document to download | |||
Documentation filtre submicronique | 0200-PHENIX-BrochureA3 |
The PNX-S series submicron filters are designed for optimum filtration of oil and particles. They must be installed downstream of a PNX-M pre-filter.
The filter elements, which have a high coalescing power, have a draining outer layer of polyester fibres. This layer is ultrasonically welded and is much more resistant than traditional reticulated foam layers.
Indispensable for most compressed air production plants ! To be installed after the dryer in the case of refrigeration drying and after the PNX-M pre-filter in all other cases.
This product is no longer in stock
Availability date:
* Select the generic if you don't know which model to choose. The sales department will contact you to determine the appropriate model.
(*) Flow rates indicated according to ISO 7183 (20ºC and 1 bar absolute) under 7 bar relative
Elimination of liquid phases at the beginning of air treatment.
Pression | Bars | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Facteur | x | 0.63 | 0.75 | 0.88 | 1 | 1.12 | 1.25 | 1.37 | 1.49 | 1.62 | 1.74 | 1.86 | 1.98 | 2.10 |
Correction factor depending on operating pressure
Detailed specifications | PNX-S |
Quality class according to ISO 8573-1:2001 | Particles: 1 |
Residual oil: 1 | |
Particle filtration | 0.01μ |
Residual oil content at 20°C | 0.01mg/m3 |
Compressed air temperature min/max | 1°C / 120°C |
Maximum operating pressure | Depending on model |
Pressure loss (initial) | 75 mbars |
Pressure loss wet belt | 110 mbar |
Maximum recommended pressure loss | 400 mbar |
Element replacement frequency* | 8,760 h / 12 months |
(*) For normal dusting and correct air quality. |