Premium filters

See the choice of models
+ -
Manufacturer Partenair
Categories Compressed air treatment, Compressed air filters
Liquid Water
Classe iso : 7
9876543210

Dry particles
>99.99% at 1µ


FP-RX1 series micronic filters are specially designed for the filtration of dry particles in compressed air networks.


    •    filtration of particles up to 1µ (ISO class 8573 = 2)

    •    filtration for dry compressed air networks

    •    saturation indicator included

    •    interior and exterior anti-corrosion protection by electrophoretic coating (E-coat®)

    •    double o-ring seal eliminates risk of contaminant bypass for added security

    •    new lower filter bowl with smart stop, avoiding excessive tightening. Easier installation.

    •    compatible with mineral and synthetic oil

    •    Compatible with non-lubricated networks

    •    manual drain

    •    compliant with the 14/68 guideline concerning equipment under pressure for type 2 gases

    •    individually tested and serialized

    •    ISO 12500 compliant design

    •    ISO 9001 certified manufacturing


Model
     
Model Input connection Flowrate (m³/h) My wish
FP 15 RX1 1/8’’ 15
FP 27 RX1 1/4’’ 27
FP 45 RX1 1/4’’ 45
FP 65 RX1 3/8’’ 65
FP 90 RX1 1/2’’ 90
FP 130 RX1 1/2’’ 130
FP 155 RX1 3/4’’ 155
FP 230 RX1 3/4’’ 230
FP 260 RX1 1’’ 260
FP 320 RX1 1’’ 320
FP 510 RX1 1’’1/4 510
FP 585 RX1 1’’1/2 585
FP 820 RX1 2’’ 820
FP 1280 RX1 2’’ 1280
FP 1550 RX1 2’’1/2 1550
FP 1640 RX1 3’’ 1640
FP 2300 RX1 3’’ 2300
FP 2740 RX1 3’’ 2740
Advise me    

* Select the generic if you don't know which model to choose. The sales department will contact you to determine the appropriate model.

The most common application is the retention of fine particles of desiccants downstream of compressed air adsorption dryers.
 
All filter bodies are manufactured from cast aluminum alloy, are protected from corrosion through  interior and exterior electrophoretic coating (E-coat®) and are coated with polyester of extremely resistant finish.

The ISO testings include an individual hydrostatic test and the affixing of a serial number for a complete traceability.

All filters are designed, tested and validated in compliance with the ISO 12500 international norm.

Detailed specifications

ISO 8573-1:2001 quality class Particles : 2
Residual oil : 2
Particle retention > 99,99% at 1μ
Residual oil content at 20°C non-applicable
Maximum compressed air temperature 120°C
Recommended compressed air temperature 25°C max.
Maximum operating pressure 16 bars
Initial average pressure drop 75 mbars
Maximum recommended pressure drop 400 mbars

Equipments / Options

FP 45 to FP 90 Pop-up saturation indicator
FP 130 to FP 2740 Differential pressure gauge

All models Manual drain

All models drain test/filter depressurization

FP 15 to FP 2740 Mural fixation (optional)

FP 15 to FP 2740 Assembly kit (optional)

FP 130 to FP 2740 Dry contact pressure gauge (optional)