Manufacturer | Partenair |
Categories | Industrial vacuum filtration, Vacuum circuit filtration, Protection by filtration upstream of vacuum pumps |
Document to download | |
D100_filtre_VLR-VX1 |
The VLR and VX1 series filters are designed to stop pollutants carried by industrial vacuum networks before they enter the pump.
The VLR series stops pollutants up to 5 microns.
The VX1 series stops pollutants down to 1 micron.
All these filters can be equipped with visible level drain pots in order to control the presence of liquids and to drain them in good time.
The range consists of 16 models covering flow rates up to 490 normal cubic meters per hour at 1 bar (A).
All filters are delivered complete with their filter element (s), a differential saturation indicator and a manual purge system.
This product is no longer in stock
Availability date:
* Select the generic if you don't know which model to choose. The sales department will contact you to determine the appropriate model.
(*) Flow rates indicated at atmospheric pressure (20 ° C and 1 Bar absolute).
Connections: parallel BSP according to ISO 7/1.
Color code of VLR elements: Green, VX1: Red.
The vacuum circuits carry a number of harmful pollutants for correct operation and for the longevity of industrial vacuum pumps.
The installation of our filters upstream of the pumps protects the latter from damage caused by solid and liquid materials.
The VLR (5µ) and VX1 (1µ) series filters effectively protect pumps, eliminate costly downtime, lower maintenance costs and increase productivity.
The filter bodies are treated against corrosion by an internal and external treatment, by cataphoresis supplemented by a very resistant polyester external finishing paint.
The new generation of filter elements, instant installation, are oleophobic and provided with an exclusive anti-retraining layer. They offer a very low pressure drop and have an increased particle retention capacity.
Grade VLR | Grade VX1 | |
Particle filtration | 5 microns | 1 micron |
Residual oil at 20°C | 1mg/m3 | 1mg/m3 |
Maximum operating temperature | 120°C | |
Initial pressure drop (clean and dry) | 20 mbar | 40 mbar |
Maximum pressure drop (Element replacement) | 100 mbar |
|
Recommended serving temperature | 25°C max. |
|
Maximum operating vacuum | Absolute vacuum |
|
Saturation indicator (A038 to A058) | Pop-up |
|
Saturation indicator (A059 to A390) | Differential pressure gauge |
|
Visible level drain pot | Optional |
Correction factor according to operating pressure
Pressure | mbar(a) | Atm. | 900 | 800 | 700 | 600 | 500 | 400 |
300 |
200 |
Torr | 760 | 675 | 600 | 525 | 450 | 375 | 300 | 225 | 150 | |
Factor | x | 1 | 0.93 | 0.86 | 0.79 | 0.71 | 0.64 | 0.57 | 0.5 | 0.43 |