Protection of vacuum pumps

See the choice of models
+ -
Document to download

Elimination of pollutants upstream of the pumps

The VLR and VX1 series filters are designed to stop pollutants carried by industrial vacuum networks before they enter the pump.

The VLR series stops pollutants up to 5 microns.

The VX1 series stops pollutants down to 1 micron.

All these filters can be fitted with visible level drain pots in order to control the presence of liquids and to drain them in good time.

The range consists of 16 models covering flow rates up to 490 normal cubic meters per hour at 1 bar (A).

All filters are delivered complete with their filter element (s), a differential saturation indicator and a manual purge system.

  • 2 filtration grades available.
  • Residual oil filtration 1 mg / m3 at 20 ° C
  • Particle filtration up to 1 µ
  • Total corrosion protection of the
  • cataphoresis filters.
  • Oleophobic filter elements.
  • Compatible with mineral or synthetic oils.
  • Low initial pressure drop and load.
  • Saturation indicators supplied as standard.
  • Manual purge valve supplied as standard.
  • Optional visible level drain pots.
  • Design in accordance with ISO 12500.
  • ISO 9001 certified manufacturing.
Model
 
Model My wish
A 3031 VX1
A 3051 VX1
A 3052 VX1
A 3071 VX1
A 3072 VX1
A 3101 VX1
A 3102 VX1
A 3122 VX1
A 3151 VX1
A 3201 VX1
A 3202 VX1
A 3251 VX1
A 3301 VX1
A 3302 VX1
A 3303 VX1
Advise me

* Select the generic if you don't know which model to choose. The sales department will contact you to determine the appropriate model.

(*) Flow rates indicated at atmospheric pressure (20 ° C and 1 Bar absolute).

Connections: parallel BSP according to ISO 7/1.

Color code of VLR elements: Green, VX1: Red.

An essential filtration


The vacuum circuits carry a number of harmful pollutants for correct operation and for the longevity of industrial vacuum pumps.
The installation of our filters upstream of the pumps protects the latter from damage caused by solid and liquid materials.


The VLR (5µ) and VX1 (1µ) series filters effectively protect pumps, eliminate costly downtime, lower maintenance costs and increase productivity.


The filter bodies are treated against corrosion by an internal and external treatment, by cataphoresis supplemented by a very resistant external polyester finish paint.


The new generation of filter elements, instant installation, are oleophobic and provided with an exclusive anti-retraining layer. They offer a very low pressure drop and have an increased particle retention capacity.

Detailed specifications

Grade VLR     Grade VX1
Particle filtration 5 microns 1 micron
Residual oil at 20°C 1mg/m3 1mg/m3
Maximum operating temperature 120°C
Initial pressure drop (clean & dry) 20 mbar 40 mbar
Maximum pressure drop (element replacement)
100 mbar
Recommended serving temperature
25°C  max.
Maximum operating vacuum Absolute vacuum

Saturation indicator (A038 à A058) Pop-up

Saturation indicator (A059 à A390) Diferential pressure gauge

Visible level drain pot Optional

Correction factor according to operating pressure

Pressure mbar(a) Atm. 900 800 700 600 500 400

300

200

Torr 760 675 600 525 450 375 300 225 150
Factor x 1 0.93 0.86 0.79 0.71 0.64 0.57 0.5 0.43