Manufacturer | Partenair |
Categories | Compressed air treatment, Compressed air filters |
Particles
|
Selon grade - Classe iso : 1 à 3
9876543210
|
Residual oil content (20°)
|
Selon grade - Classe iso : 1 à 4
9876543210
|
Document to download | |
C130_filtre_MP |
4 series of filters available for filtration at a suitable price.
2 ranges available for a maximum pressure of 20 and 50 bars.
3 ranges for pressures of 50, 100 and 350 bars.
These ranges include 6 filtration grades:
- Cyclonic separator, 25µ, 5µ, 1µ, 0.01µ, activated carbon.
This product is no longer in stock
Availability date:
* Select the generic if you don't know which model to choose. The sales department will contact you to determine the appropriate model.
(*) Flow rates indicated according to ISO 7183 (20 ° C and 1 Bar absolute) at nominal operating pressure.
(1) Maximum operating pressure: 20 bars (20 HP series), 50 bars (50 HP series)
(2) Filters supplied with drain plug. High pressure air vents available as an option.
(3) Differential pressure gauge available as an option for 20 HP series filters.
(4) Maximum service temperature: 120 ° C except for AC grade: 25 ° C.
(5) Silicone-free manufacturing available on request (Contact us)
The 25 HP and 50 HP series medium pressure filters use die-cast aluminum bodies that offer an economical alternative to stainless steel body models.
All filter bodies are protected, internally and externally, by electrophoresis, supplemented by an extremely resistant external polyester finish paint.
The filter elements, of the interlocking type, are fitted with 2 O-rings for sealing and are available in 5 filtration grades to suit all applications.
As a guarantee of maximum safety, the ISO control procedures for these filters include an individual hydrostatic test and the affixing of a serial number for full traceability.
All 25 HP and 50 HP series filters have been designed and tested according to the international standard ISO 12500.
Correction factor according to operating pressure (Series 20 HP )
Pressure | Bars | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 |
Factor | x | 0,45 | 0,55 | 0,63 | 0,71 | 0,77 | 0,84 | 0,9 | 0,95 | 1 |
Correction factor according to operating pressure (Series 50 HP )
Pressure | Bars | 4 | 6 | 8 | 10 | 15 | 20 | 30 | 40 | 50 |
Factor | x | 0,14 | 0,22 | 0,28 | 0,34 | 0,47 | 0,56 | 0,7 | 0,85 | 1 |