FLOTIP mass flow meter

See the choice of models
+ -
Document to download

Simple and efficient


The FLOTIP model F500 and F800 flowmeters are designed for flow measurement at points of use.

Their attractive price allows you to economically optimize production systems and reduce compressed air consumption and operating costs.

Their Bluetooth interface facilitates the setting procedure and the reading of the data thanks to a specific application. (Availability end of 2018)

The F500 is ideal for everyday applications where an affordable tester is satisfactory.

The F800 will be better suited for locations that are difficult to access or require increased accuracy or traceability of data thanks to its integrated recorder and its optional pressure measurement.

  • Mass flow measurement, independent of pressure and temperature
  • Standard version F500, Pro version F800
  • 1.5% (F800) and 3% (F500) accuracy
  • Several output signals available:
  • - Analog 4 ... 20 mA and pulses
  • - Modbus digital
  • Simplified installation, no stabilization section required upstream or downstream of the flow meter
  • Full flow measurement, no interpolation or bypass
  • Display by 4 LEDs
  • Available in DN8, DN15, DN20, DN25 threaded
  • F800 supplied with data logger as standard
  • Pressure measurement optional on F800
Model
   
Model Description My wish
FLOTIP F500.08

DN8 avec afficheur

FLOTIP F500.15

DN15 avec afficheur

FLOTIP F500.20

DN20 avec afficheur

FLOTIP F500.25

DN25 avec afficheur

FLOTIP F800.08

DN8 avec afficheur & enregistreur

FLOTIP F800.15

DN15 avec afficheur & enregistreur

FLOTIP F800.20

DN20 avec afficheur & enregistreur

FLOTIP F800.25

DN25 avec afficheur & enregistreur

FLOTIP F810.08

DN8 avec afficheur/enregistreur & pression

FLOTIP F810.15

DN15 avec afficheur/enregistreur & pression

FLOTIP F810.20

DN20 avec afficheur/enregistreur & pression

FLOTIP F810.25

DN25 avec afficheur/enregistreur & pression

Advise me  

* Select the generic if you don't know which model to choose. The sales department will contact you to determine the appropriate model.

Detailed specifications

Data

F500 F800
Measuring range See the separate table
Accuracy 3% of reading 1.5% of reading
Pressure range 0 … 1.0 MPa
Power supply 18 … 30 VDC / 120 mA
Gas Air, Nitrogen Non-corrosive gases, calibration up to 2 different gases
Temp. ambient 0° … +50°C
Temp. transport -30° … +70°C
Response time T90 = 1 sec T90 = 0.1 sec
Output signal (only 1 possible)

- 4…20 mA pulses, isolated

- RS-485 (Modbus/RTU)

Interface USB for data reading (F800 uniquement)
Materials

Air and wet parts connection : aluminium alloy.

Box : PC + ABS

Classification IP54
Electrical connection 2 x M8, 4-pole
Connection Tapped, ISO 7-1: DN8, DN15, DN20, DN25
Certifications  CE, RoHS

Additional data F 800

Data logger Capacity : 10 000 000 values
Channels : up to 3 channels
Sampling: 1 sec … 1h
Pressure option  Range : 0 … 1.0 MPa
Accuracy :  1 % Full scale

Measuring ranges [m³ / h]


DN8
DN15 DN20 DN25
Santard range (S) 0...15 0…60 0…120 0…210
Low range(L) 0…3 0…12 0…24 0…42

Measures indicated under the following conditions:

• Standard air flow

• Reference pressure: 1000 hPa

• Reference temperature: 20 ° C

Gas table

       
A Air
B CO2
C O(decreased/de-oiled)
D N2
E N2O
F Ar
G Natural Gas (mix ratio)
H H2 (real gas calibration)
I Other gas (Specify)
K He (real gas calibration)
L C3H8
Z No gas

The flowmeters are calibrated on an air bench.

On request the calibration can be carried out with a different gas

Order details model F 500 (air and N2 only)

Code Range  Output  Description
FLOTIP F500 F500, Mass flow meter precision 3% of reading, 24 VDC, 
cable : 5m, M8, open ends
F500.08 DN 8 Tapped
F500.15 DN 15 Tapped
F500.20 DN 20 Tapped
F500.25 DN 25 Tapped
OPTIONS
Standard S Standard measuring range
MDB 1500 L Low measuring range
MDB 1450 A Analog output e 4…20 mA, + pulses
MDB 1460 B Digital output Modbus/RTU

Order details for models F800 / F810

Code 

Range Output Gas 1  Gas 2 Description

FLOTIP F800

F800, mass flow meter, data logger, accuracy 1.5% of reading, 24 VDC, cable 5m, M8 open ends

F800.08 DN 8 Tapped
F800.15 DN 15 Tapped
F800.20 DN 20 Tapped
F800.25 DN 25 Tapped

FLOTIP F810

Same as F800 + pressure sensor

F810.08 DN 8 Tapped, pressure sensor 10 barg, 1% full scale
F810.15 DN 15 Tapped, pressure sensor 10 barg, 1% full scale
F810.20 DN 20 Tapped, pressure sensor 10 barg, 1% full scale
F810.25 DN 25 Tapped, pressure sensor 10 barg, 1% full scale

Options

S Standard measuring range
MDB 1500 L Low measuring range
MDB 1480 A Analog output 4…20 mA, + pulses 
MDB 1490 B Digital output Modbus/RTU
A-K B-Z See gas table above