Manufacturer | Partenair |
Categories | Measure, Flowmeters for compressed air and gas, Insert flowmeters |
Document to download | |
Pito |
The Pito 570.240 is based on the PITOT principle to measure the flow.
Installed in the state of the art, the sensor can perform measurements in humid and polluted gases, for example directly at the outlet of a compressor.
• Measurement of flow and consumption in untreated air or at high flow speeds
• Possible measurement at the compressor outlet
• Tube diameters from 1 "to 10". Other diameters on request
• Insertable sensor, easy installation under pressure via a ball valve
• Applications at high temperatures up to 200 ° C
• No mechanical wear parts
• All parts in contact with the measuring fluid are made of stainless steel
This product is no longer in stock
Availability date:
* Select the generic if you don't know which model to choose. The sales department will contact you to determine the appropriate model.
The internal self-calibration of the sensor guarantees great long-term stability and good thermal stability.
This flow meter can be used on compressed air and non-corrosive gases.
It can be installed in the pressure pipe by means of a ½ "ball valve.
Various output signals allow the sensor to be connected to PARTENAIR and / or other manufacturers' displays / recorders.
The PITO 570.240 has an optional color screen with display of measured values and sensor parameters:
- Instant flow
- Total counter
- Pressure
- Evolutionary bar graph of instantaneous flow.
Inch | mm | Flow range in m3/h | |
Mini. | Max. | ||
1" | 27.3 | 15.5 | 319 |
1¼” | 36 | 27.5 | 575 |
1½” | 41.9 | 38 | 791 |
2” | 53.1 | 62 | 1295 |
2½” | 68.9 | 106 | 2215 |
3” | 80.9 | 147.5 | 3073 |
4” | 100 | 225.5 | 4711 |
5” | 125 | 353.5 | 7378 |
6” | 150 | 509.5 | 10637 |
8” | 200 | 908 | 18955 |
10” | 250 | 1420.5 | 29652 |
Air flow range at 6 bar, 50 ° C and 90% air humidity. For other gases and other conditions, download the software "Flow Range Calculator" - from our website www.partenair.fr
All the values above correspond to the standard flow rates for P = 1000 hPa and T = 20 ° C.