NG filters

See the choice of models
+ -
Manufacturer Partenair
Categories Compressed air treatment, Compressed air filters
Particles
Classe iso : 2
9876543210
Residual oil content (20°)
Classe iso : 2
9876543210
Document to download

Oil vapor and smell filtration


The CF series filters use adsorption to capture oil vapors present in the compressed air.

They are also recommended for eliminating smells and must be installed downstream of a prefilter + deoiler combination. Theoretically, that makes for a 100% filtration.

The range consists of 18 models covering flows of up to 17.500 cubic meters per hour und a pressure of 7 bars.

All filters come complete and with their filter element(s), a differential saturation indicator and, depending on models, and a manual drain.


    •    0.003 ppm residual oil vapors filtered at 20°C (ISO class 8573 = 1)

    •    filters equipped with manual drains

    •    chrome-based anti-corrosion protection

    •    new patented venturi-wave™ technology, without turbulence

    •    filter elements with color code to avoid any inadvertent inversion

    •    compatible with mineral and synthetic oil

    •    Compatible with non-lubricated networks

    •    silicone-free filters, compatible with “air paint” applications

    •    compliant with the 14/68 guideline concerning equipment under pressure for type 2 gases

    •    ISO 9001 certified manufacturing



Model
     
Model Input connection Flowrate (m³/h) My wish
NG 02 CF ¼" 34
NG 03 CF 3/8" 59
NG 04 CF ½" 85
NG 06 CF ¾" 127
NG 07 CF ¾" 175
NG 08 CF 1" 267
NG 10 CF 1" ½ 437
NG 11 CF 1" ½ 612
NG 12 CF 2" 681
NG 13 CF 2" ½ 993
NG 14 CF 2" ½ 1317
NG 15 CF 2" ½ 1750
NG 16 CF 3" 2039
NG 17 CF 3" 2549
Advise me    

* Select the generic if you don't know which model to choose. The sales department will contact you to determine the appropriate model.

(*) Flow rates indicated according to ISO 7183 (20ºC and 1 bar absolute) under 7 bar relative

Absolute deoiling

The DELTECH NG CF series filters are designed to capture oil vapors still present downstream of a submicronic filter. They remove the smell and taste of compressed air: an essential point for the food industry (air in contact with food) or for breathable air.

The filters must be installed downstream of a submicronic filter. Efficiency is guaranteed for a concentration of upstream oil mist of up to 0.01ppm.

All filter bodies are made of aluminium protected against corrosion by a chrome based internal coating.

These filters work with adsorption and have a constant pressure drop and are thus not equipped with a saturation indicator with differential pressure reader.


Detailed specifications

ISO 8573-1:2001 quality class Particles : -/-
Residual oil: 1
Particle retention -/-
Residual oil content at 20°C 0,03 ppm
Maximum compressed air temperature 55°C
Recommended compressed air temperature 20°C
Maximum operating pressure 16 bars
Initial average pressure drop 70 mbars
Filter element replacement 1000 hours of operation

Equipments / Options Models
Pop-up saturation indicator N/A
Differential pressure gauge N/A
Automatic free float drain All models
Manual drain N/A
Purgeur Captair compact optionnel recommandé Captair compact drain recommended (option) N/A
Mural fixation (optional) All models
Assembly kit (optional) All models
Dry contact pressure gauge (optional) N/A

Correction factor depending on operating pressure

Pressure Bars 4 5 6 7 8 9 10 11 12 13 14 15 16
Factor x 0,62 0,75 0,87 1 1,12 1,25 1,37 1,5 1,62 1,75 1,87 2 2,12