The ambient air drawn in by the compressor contains quantities of pollutants which must be removed before this air can be used for breathing purposes.
Water, oil and particles are not the only ones among these contaminants.
Toxic gases, such as carbon monoxide (CO) and carbon dioxide (CO2) must be brought below the thresholds imposed by standard EN 12021.
This standard sets the values to be observed for the quality of the air supplied for use with respiratory protection devices (diving suits, hoods, mouthpieces ...).
The CLIN'AIR series breathing units, compact and simple to install, allow you to safely produce air quality in all respects in accordance with the European standards in force.
This product is no longer in stock
Availability date:
* Select the generic if you don't know which model to choose. The sales department will contact you to determine the appropriate model.
The units are supplied with separate upstream filtration (prefilter + oil separator).
These filters are equipped with differential pressure gauge and purge valve by timed solenoid valve.
Pollutants | Standard NF-EN 12021 | CLIN'AIR treatments units |
Residual oil | 0,5 mg/m³ | 0,003 mg/m³ |
Particles | Threshold below the national exposure limit | Filtration > à 99,99% à 0.01µ |
Water | Dew point 5 ° C below the lowest expected ambient temperature. If this temperature is not known, the imposed dew point is at least -11 ° C. | Dew point -40 ° C under pressure |
CO | 15 ppm Maximum | < 5 ppm |
CO2 | 500 ppm maximum | < 500 ppm |