CLIN’AIR breathing air units

See the choice of models
+ -
Manufacturer Partenair
Categories Production of compressed breathing air
Document to download

Compliant with EN 12021 EUROPEAN PHARMACOPOEIA


The ambient air drawn in by the compressor contains quantities of pollutants which must be removed before this air can be used for breathing purposes.

Water, oil and particles are not the only ones among these contaminants.

Toxic gases, such as carbon monoxide (CO) and carbon dioxide (CO2) must be brought below the thresholds imposed by standard EN 12021.

This standard sets the values to be observed for the quality of the air supplied for use with respiratory protection devices (diving suits, hoods, mouthpieces ...).

The CLIN'AIR series breathing units, compact and simple to install, allow you to safely produce air quality in all respects in accordance with the European standards in force.

  • Compliant with European and international standards for the quality of compressed breathing air.
  • Compact units, fully assembled and tested.
  • Purification on multi-adsorbent composite cartridges, facilitates maintenance operations.
  • Eliminate CO and CO2 and other toxic gases below the imposed limit values.
  • Dew point -65 ° C brought to atmospheric pressure.
  • Simple and quick installation.
  • Electronic dryer cycle control module with alarm report.
  • Saturation and purge indicators by timed solenoid valve on prefilter and oil separator filter.
  • Energy saver with cycle control according to dew point setpoint (available as an option)
  • ISO 9001 manufacturing.
Model
    Débit m3/h
Model Input connection Entrée Utile My wish
CLR 10 3/8’’ 14 10
CLR 15 3/8’’ 20 15
CLR 25 3/8’’ 32 24
CLR 45 1’’ 59 44
CLR 70 1’’ 93 70
CLR 110 1’’ 148 110
CLR 140 1’’ 183 138
CLR 240 2’’ 292 236
CLR 280 2’’ 367 275
CLR 410 2’’ 550 413
CLR 550 2’’ 1/2 734 550
CLR 830 2’’ 1/2 1101 826
Advise me      

* Select the generic if you don't know which model to choose. The sales department will contact you to determine the appropriate model.

The units are supplied with separate upstream filtration (prefilter + oil separator).

These filters are equipped with differential pressure gauge and purge valve by timed solenoid valve.

Detailed specifications

Pollutants Standard NF-EN 12021 CLIN'AIR treatments units
Residual oil 0,5 mg/m³ 0,003 mg/m³
Particles Threshold below the national exposure limit Filtration > à 99,99% à 0.01µ
Water Dew point 5 ° C below the lowest expected ambient temperature. If this temperature is not known, the imposed dew point is at least -11 ° C. Dew point -40 ° C under pressure
CO 15 ppm Maximum < 5 ppm
CO2 500 ppm maximum < 500 ppm