Capacitive technology steam drain- 950 T

See the choice of models
+ -
Document to download

No unnecessary loss of compressed air!


The 950 T condensate trap represents the new generation of economical and intelligent
traps.
Equipped with internal sensors, it detects the presence of condensate and triggers the purge
until complete elimination of liquids.
Small but powerful, it can remove up to 70 liters of condensate per hour.
Its Viton diaphragm valve is protected by a built-in strainer and a sensitive operating test
makes it possible to check that it is working properly.
The 950 T operates fully automatically, and adapts in real time to the volume of condensate
to be evacuated.
It offers an unequaled value for money.

  • Intelligent automatic air vent, electronically controlled.
  • Automatic detection of condensate, no adjustment to be made.
  • Adapts automatically to the volume to be evacuated without unnecessary loss of air.
  • Removes up to 70 liters of condensate per hour at 7 bars.
  • Integrated protection strainer.
  • Manual operation test
  • Integrated anti-siphon device.
  • Alarm light.
  • Viton® solenoid valve membrane.
  • IP 65 protection.
  • Small footprint.
  • Unmatched value for money.
Model
 
Model My wish
950 T
Advise me

* Select the generic if you don't know which model to choose. The sales department will contact you to determine the appropriate model.

This new generation steam trap is essential for all compressed air networks.

Its installation is extremely simple and quick. It mounts in place of manual traps.

Its operation is fully automatic and without adjustment because it adapts to each type of
network and to each volume of condensate to be eliminated.

Thanks to its internal level detectors, it regularly checks for the presence of condensate (5 cc
minimum). In this case, the purge is triggered automatically until the liquids are completely
eliminated.
If it does not detect liquids, the controller will open the valve for a few tenths of a second in
order to remove any air bubbles that may prevent correct detection.

The valve is protected by an integrated strainer and a sensitive functional test allows the
user to verify its correct operation.
An alarm light indicates any problem.

Detailed specifications

Maximum operating pressure  15 bars
Ambient temperature min / max   +1 à +60°C
Condensate temperature min / max +1 à + 80°C
Maximum evacuated flow (under 7 bars) 70 liters/h.
Detectable condensate volume 5 cc mini.
solenoid valve membrane Viton®
condensate inlet 3/8” threaded
Condensate outlet Tube 10 mm
Power supply DIN 40050
Voltage 240/1/50
Pending consumption 0,5 VA
Drainage consumption 6,5 VA
Other voltages Upon request
Protection  IP 65
Construction  ABS
Weight  280 g